Door-frame-install – Oldcastle BuildingEnvelope 3000 Series Thermal MultiPlane User Manual
Page 50

FG-3156
FG-3155
FG-2145
LEAVE FRONT OF DOOR JAMB
CLEAR OF SEALANT FOR DRAINAGE
SUB-SILL IS BED IN
SEALANT AT DOOR JAMB
RUN SEALANT MINIMUM 1"
ABOVE BACK OF SUB-SILL
NOTES:
1) USE SHEAR BLOCKS AS SHOWN IN FRAME ASSEMBLY SECTION OF THIS MANUAL TO SECURE HORI-
ZONTALS TO TUBULAR FRAMES.
2) DOOR FRAME IS ANCHORED BY FASTENERS THROUGH THRESHOLD AND DOOR FRAME HEADER.
3) DO NOT FABRICATE STANDARD 2 PIECE POUR & DEBRIDGED FRAME EXTRUSIONS FOR DOOR
FRAMES. IF THERMAL FRAME IS REQUIRED,OPTIONAL THERMAL DOOR FRAME FG-3389 OR FG-3444
MAY BE USED IN CONJUNCTION WITH THERMAL DOORS.
4) WHEN USING THE CENTER SET SYSTEM, THE TWO-PIECE OR TUBULAR FRAMING OPTION ARE AVAIL-
ABLE AS SHOWN ABOVE. WHEN USING EITHER THE FRONT SET OR BACK SET SYSTEM ONLY
THE TUBULAR OPTION IS AVAILABLE. THE VERTICAL FOR THE FRONT OR BACK SET OPTIONS IS FG-
3287.
DOOR FRAME INSTALLATION
1"
50
S E R I E S 3 0 0 0 T H E R M A L M U L T I P L A N E I N S T A L L A T I O N M A N U A L