CAP SEAL

FASTENERS

KEEP FACE OF BRIDGE

CLEAR OF SEALANT FOR

WEEPAGE.

FS-202

(#8 X 1/2" PPH)

SEAL BETWEEN

BRIDGE AND HORIZONTAL

TOOL SEALANT AT MULLION

AND HORIZONTAL TO FORM

WATER TIGHT SEAL

BED FASTENERS

IN SEALANT

FG3000-PP-53

FUNNEL BRIDGE

(PART# 13664)

APPLY SEALANT TO HORIZONTAL

AND FACE OF MULLION PRIOR

TO INSTALLING BRIDGE.

BRIDGE INSTALLATION FOR MULTIPLANE SSG

INSTALL HP-1004 WEEP

BAFFLE INTO BRIDGE

PRIOR TO INSTALLING

FACE CAP.