Measuring-cutting-ssg – Oldcastle BuildingEnvelope 3000 Series Thermal MultiPlane User Manual
Page 7

1"
2"
5/8"
1-1/16"
Sub-Sill Height
Mullion Height
O
ve
rall
F
rame
Height
FRAME FABRICATION
(SSG Installations)
Measure ROUGH OPENING to determine FRAME WIDTH and FRAME HEIGHT
dimensions. Allow 1/4” minimum clearance for shimming and caulking around
perimeter of frame. (FG-3413 Sill Receptor requires minimum 3/8“ joint at head)
(Reference page 6 for elevation and terminology)
Cut material to size per dimensions given below :
Frame Members
Sub-Sill or Sill Receptor:
Frame Width Plus1/4”
Mullions & Jamb (see Dtl. A)
Overall Frame Height Minus 3” Minus Sub-sill
Height (FG-3223 Minus 3/8”,
FG-3413 Minus 1 /2”)
Head & Sill
Frame Width
Horizontal (Screw Spline Assembly)
Day Light Opening (D.L.O.)
Horizontal (Shear Spline Assembly)
D.L.O. Minus 1/16”
Horizontal Glazing Beads & Fillers:
D.L.O. Minus 1/16”
Accessories
Head & Sill Exterior Gaskets:
D.L.O. Plus1” Plus 3/8” per foot.
Head & Sill Interior Gaskets:
D.L.O. Plus 3/8” per foot.
Horizontal Gaskets:
D.L.O. Plus 3/8” per foot.
Vertical Gaskets:
D.L.O. Plus1” Plus 3/8” per foot
Other Members (as required)
Horizontal Glazing Adaptors:
D.L.O. Minus 1/16”
Vertical Glazing Adaptors:
D.L.O. Plus 7/8”
Door Jamb:
Rough Opening Minus Head Joint
Detail “A”
7
S E R I E S 3 0 0 0 T H E R M A L M U L T I P L A N E I N S T A L L A T I O N M A N U A L