4 kontron reset, 5 kontron post code value, 6 kontron diagnostic status – Kontron AM4220 User Manual
Page 54: Figure 5-1: kontron diagnostic status sensor
39
www.kontron.com
5.1.2.1.4
Kontron Reset
5.1.2.1.5
Kontron POST Code Value
5.1.2.1.6
Kontron Diagnostic Status
Table 5-5:Kontron reset sensor
Event/Reading type
code
Sensor type
Sensor specific offset Event trigger
03h
CFh
OEM Kontron
RESET
00h
01h
State Asserted /
State Deasserted
Event Data 2: Reset Type
00h: Warm reset
01h: Cold reset
02h: Forced Cold [Warm reset reverted to Cold]
03h: Soft reset [Software jump]
Event Data 3: Reset Source
00h: IPMI Watchdog [cold, warm or forced cold]
(IPMI Watchdog2 sensors gives dditional details)
01h: IPMI commands cold, warm or forced cold]
(chassis control, fru control)
02h: Processor internal checkstop
03h: Processor internal reset request
04h: Reset button [warm or forced cold]
05h: Power up [cold]
06h: Legacy Initial Watchdog / Warm Reset Loop Detection
* [cold reset]
07h: Legacy Programmable Watchdog [cold, warm or forced
cold]
08h: Software Initiated [soft, cold, warm of forced cold]
09h: Setup Reset [Software Initiated Cold]
FFh: Unknown
Table 5-6:Kontron POST code value sensor
Event/Reading type
code
Sensor type
Sensor specific offset Event trigger
6Fh
C6h
OEM Kontron POST
Code Value
14h
POST Code Error Event Trigger
Event Data 2: POST Low
Event Data 3: POST High (always 00h)
Figure 5-1:Kontron diagnostic status sensor
Event/Reading type
code
Sensor type
Sensor specific offset Event trigger
6Fh
C9h
OEM Kontron
Diagnostic Status
00h
Diagnostic Started
01h
Diagnostic PASS
02h
Diagnostic FAIL