4 hot swap capability – Kontron AM4220 User Manual
Page 19
4
www.kontron.com
1.4
Hot Swap Capability
The AMC supports Full Hot Swap capability as required by AMC.0 R2.0. It can be removed from or installed in
the system while it is on (without powering-down the system). Please refer to the AMC.0 R2.0 specification
for additional details.
Vibration
•
The board is designed to meet the following requirements according to EN 300 019, Telcore GR-
63 and IEC 60068:
•
Operating:
• 5 Hz to 200Hz 0.2G, 5mm/s (sinusoidal)
• 5 Hz to 100Hz: 0.1G @ 0.1 Octave/minute (sinusoidal)
• 5 Hz to 100Hz: 1G @0.1 Octave/minute (sinusoidal)
• 0,02 m²/s³ ASD, 5-10Hz +12dB/oct, 10-50Hz 0dB/oct, 50-100Hz -12dB/oct (random)
•
Non-Operating (packaged enclosure):
• 5 Hz to 200Hz 2G, 5mm/s (sinusoidal)
• 0,02 m²/s³ ASD, 5-10Hz +12dB/oct, 10-50Hz 0dB/oct, 50-100Hz -12dB/oct (random)
• 5 Hz to 20 Hz: 0.01g²/Hz (random)
• 20 Hz to 200 Hz: -3dB/octave (random)
Shock
•
The board is designed to meet the following requirements according to EN 300 019, Telcore GR-
63 and IEC 60068:
•
Operating:
•
3G, 11ms Shock
•
Non-Operating
•
18G, 6ms Shock
•
1000mm/all edges and corners Free Fall (packaged)
•
100mm/all edges and corners Free Fall (unpackaged)
Safety
•
CB report to IEC 60950-1, complies with EN/CSA/ UL 60950-1.
•
The board is designed to meet the following flammability requirement (as specified in Telcordia
GR-63-CORE):
•
UL 94V-0/1 with Oxygen index of 28% or greater material
Electromagnetic
Compatibility
•
The board is designed to meet or exceed of the following specifications/requirements (assuming
an adequate carrier/chassis):
•
FCC 47 CFR Part 15, (USA)
•
EMC Directive 89/336/EEC (Europe)
•
EN55022 (Europe)
•
EN55024 (Europe)
•
CISPR22
•
VCCI (Voluntary Japan Electromagnetic Compatibility requirement)
•
EN 300 386, Electro-Magnetic Compatibility (EMC) Requirements for Public Telecommunication
Network Equipment; Electromagnetic Compatibility (EMC) Requirements
•
Telcordia GR-1098
ETSI/NEBS requirements
•
This board is designed to meet NEBS Level 3, Earthquake Zone 4
Features
Description