beautypg.com

2081 rolled steel flange mounting in concrete pit – ETS-Lindgren 2081 Turntable Series 1.2m/1.5m (Archived) User Manual

Page 19

background image

MODEL 2080 / 2081 TURNTABLE SERIES

Turntable Installation Instructions

© ETS-LINDGREN L.P. – JANUARY 2003

15

REV C – PN 399228

2081 ROLLED STEEL FLANGE MOUNTING
IN CONCRETE PIT


Mounting to concrete is the same with the exception of the
mounting hardware. You should have ½-13 wedge type concrete
anchors. Instead of the #14 x 1” square socket flat head screws,
you will use 1/4 x 1-3/4 Phillips flat head TAPCON screws.

You will need a ½” hammer drill with a ½” x 12” hammer drill bit
and a 3/16 x 6” hammer drill bit. Instead of the 1/4 x 1-3/4”
tapcons, you will need ¼-20 x 1” phillips flat head thread rolling
screws for mounting the flange to the rolled steel flange. The drill
hole size for ¼-20 x 1” thread rolling screws is 0.238 - 0.242 (B or
C drill). You will also want a small vacuum to clean up concrete
dust so that it does not get into the screw threads making them hard
to screw in.

NOTE: When drilling holes, watch out for buried conduit and pit
drain pipes. Also drill ½” hole as deep as you can. Drill 3/16”
holes about 3 to 4 inches deep.

2081 WELDED CHAMBER WITH STEEL
PIT & STEEL RAISED FLOOR


When mounting to a steel pit and steel raised floor you will not
need ¼” anchor/shim plates. You will need a ½-13 tap, 27/64”
drill for tap, ½-13 x 5” square head set screw and flange nuts.
Drill 27/64” diameter. holes in locations shown in the illustrations
at the back of this manual. (Model 2081-6x). Tap each hole as you
drill it and then screw in ½-13 x 5” set screw so that the table does
not move as you go around each location. Proceed with leveling
instructions in step 11 of the “Installation” section of this manual.

Archived 3/18/10