ETS-Lindgren SMART 1000 Mini-Reverb Cell User Manual
Page 14

14
|
Maintenance
9.
Re-lubricate all finger stock and channel.
10. Beginning in the middle of the side of the frame, start installing the
vinyl seal by inserting it by hand into the channel opening. Go around
the door frame so that the vinyl seal covers the finger stock completely.
11. Using the right angle corner of a rectangular piece of sheet metal
(about 4 in x 8 in x 16 ga.) or a wide putty knife, gently push the vinyl
seal between the two rows of finger stock to the final position at the
base of the channel. Use caution at the corners to insert the vinyl seal
behind one finger at a time.
12. If fingers are broken during insertion of the vinyl seal, a patch section
must be inserted.
F
INGER
S
TOCK
R
EPAIR
For All Doors
You can replace recessed finger stock without removing the door.
Finger stock 81D-6L can be replaced in sections if a maximum of 10 inches is
damaged.
1.
Remove broken or loose pieces with needle-nose pliers.
2.
Select an overlapping piece not less than four inches longer than the
missing section and insert new finger stock.
For Door Type D and Type E