beautypg.com

EFCO Dorma RTS 88 User Manual

Page 12

background image

BAB 7/01

PAGE 10

INSTALLATION OF THE CLOSER IS IDENTICAL FOR THE 1 3/4" AND 2" HEADERS.

THE 2" HEADER IS SHOWN IN THE FOLLOWING DETAILS.

SECTION III CLOSER PREPARATION AND

INSTALLATION

(CON’T)

A. BUTT HINGE, CONTINUOUS HINGE, CENTER PIVOTS

(CON’T)

1. CLOSER PREP AND INSTALLATION STEPS FOR 1 3/4" AND
2" HEADER/T’BAR

(CON’T)

LOCATING SCREWS

ANGLE BRACKET (C)

1/4" LOCK WASHERS

& 1/4-20 HEX NUTS

DORMA RTS 88

OVERHEAD CLOSER

"F" CLIP (C)

F045 (2" HEADER ONLY)

HINGE/

PIVOT

JAMB

2" HEADER/TRANSOM BAR (SHOWN)

1/4-20 X 1/2" HXMS

& LOCK WASHERS (C)

F045

(2" HEADER ONLY)

B.

WHILE HOLDING THE CLOSER AT A 15˚ ANGLE TO THE HDR/T-BAR, INSERT

THE CLOSER MOUNTING LUGS INTO THE "F" CLIP AND RAISE THE OPPOSITE

END OF THE CLOSER TO ALIGN THE ANGLE CLIP SCREW HOLES WITH THE

THREADED HOLES IN THE CLOSER END. SECURE THE CLOSER IN PLACE WITH

TWO 1/4-20 HEX BOLTS AND WASHERS.

C.

TIGHTEN THE FILLISTER HEAD SCREWS AND RECHECK TO MAKE SURE

THAT ALL SCREWS / NUTS ARE TIGHT.

15˚ APPROX.