EFCO CORPORATION 7/2012 PART NO. Y306

Page 17 of 28

Series 5600 Silicone Structural Glazed Installation Instructions

Section VI: Glazing Preparation

Installation of Glazing Adaptors at Openings for ¼” Infill

A.)

Position vertical adaptor as shown. Place horizontal adaptors between verticals.
Seat adaptors by applying sealant to all four corners.

MIN.

1/

8"

Seal at Captured Glazing Adaptors

Continuously seal gasket

raceway with sealant prior to
installing adaptors.

Cut Formula

Vertical = D.L.O. + 1”

Horizontal = D.L.O. – 1/16”

Note: Vertical adaptors will need a minimum of 1/8”

clearance above joint plug, free FROM sealant.