Series 5500 Advanced & Alternate Installation Instructions

Section V: Vertical Splice Joints

STEP #8 INSTALL INTERIOR GASKETS, GLAZING, AND EXTERIOR GASKETS

A. Install the interior gaskets allowing them to span the mullion splice joint.

B. Set the glazing into the opening as previously instructed.

C. Apply the exterior vertical drive-in wedge gaskets into the vertical mullions as

shown in Section VI of the Standard Installation Instructions.

D. Apply the horizontal pressure covers and horizontal exterior drive-in wedge

gaskets at the top and bottom of the lite as shown in the Standard Installation

Instructions.

GLAZING INFILL

INTERIOR GASKETS

(Runs continuously

through splice joint)

EXTERIOR GASKETS

(Runs continuously

through splice joint)

GLAZING ADAPTERS

(When required)