Detex MS-2049F User Manual
Detex Safety
INS-2049F April 20, 2007
INSTALLATION INSTRUCTIONS FOR MAGNETIC SWITCH MS-2049F
Detex Corporation, 302 Detex Drive, New Braunfels, Texas 78130 (830)629-2900 1-800-729-3839 FAX (830)620-6711
E-Mail: [email protected] Internet: www.detex.com
ELECTRICAL
SPECIFICATIONS
SWITCH (SPDT)
MAXIMUM CONTACT RATING;
500 mA at 24V
BLK COM
RED OPEN
WHT CLOSED
WHT
RED
BLK
SHOWN DOOR SECURE
MS-2049F POSITION
The preferred position of the mag-
netic switch is the top of the door,
centered approximately 6” from the
edge of the door, as shown.
Contacts should be installed so that
the door cannot be opened more than
2 inches without causing an alarm
condition.
1 - 1/16”
3 - 1/2” CENTERED ON PLATE
SWITCH MS-2058
SWITCH - PLATE
1.25X4.875X.075
HOLE CENTERS SAME
AS MAGNET PLATE
SCREWS FOR SWITCH
AND MAGNET ARE
#8-32
P/N MS-2053
MAGNET MS-2057
MAGNET PLATE
1.25X4.875X.075
6”
TO CENTER OF MAGNET
DOOR
1-1/4” MIN
NOTE: DOOR AND FRAME PREPARATION
PER ANSI A115.2
1 - 1/2”
DIMENSIONS:
A = 3-1/2” MIN B = 4-1/8” C = 4-15/16” MIN
NOTE: The dimensions given in the illustration apply to the door and
frame preparation for top of door or latch side installation.
Special screws, #8-32 x 1/4” flat head are provided.
Special attention must be given to the alignment of the switch and
magnet, especially longitudinal. The maximum allowable misalign-
ment in any direction is 1/8”.
DETEX INS2049F