Detex AO19-1 Pull User Manual
Page 4
Installation
Hanger Plate Location for Single Pull Units
The hanger plate should be located 5/8" from the outside edge of the hinge jamb, (typical 1 3/4”
frame face) level and 1-1/16” above bottom of the door frame. The goal is to be able to pass the
door under the main shaft of the motor. Bar clamp the hanger plate. Using hanger plate mark and
drill holes into the header frame or solid wall or wall stud. Fasten using appropriate type and size
screws (Detex recommends using flat head type).
Note: Drilling debris accumulated in hanger groove tracks can prevent the operator from seat-
ing uniformly when mounting. Remove debris with thin brush. Masking tape can also be used to
prevent debris from collecting in groove.
Lift the operator and lower onto the webs of the hanger plate bracket. Be sure both top and
bottom are engaged.
104851 Page 4
SECURE HANGER WITH SCREWS
HINGED SIDE
5/8”
1-1/16”
Hanger Plate
Once they are seated, pull down until unit is completely flush and screws can be replaced in top
corners.
Replace
Screw
here
Replace
Screw
here