Model 7600 Family PWC User’s Manual
22
Follow these steps to access and configure the
items in the CONFIG menu. Refer to Figure 2.
1.
From the DIAG display press the ZERO key,
or from normal weighing mode, move Switch
1 to Menu mode or OPEN position, then
press the ZERO key…
CONFIG is displayed.
2.
Press the UNITS key…
FILTER is displayed.
3.
Press the UNITS key…
The current setting is displayed. Use the
ZERO key to toggle between FLTR ON
and FLTR OFF
4.
Press the UNITS key…
Filter selection is stored.
5.
Press the ZERO key…
BAUD is displayed.
6.
Press the UNITS key…
The current setting is displayed. Use the
ZERO key to toggle between the five
choices: 1200, 2400, 4800, 9600, or
19200 baud
7.
Press the UNITS key…
Baud rate selection is stored.
8.
Press the ZERO key…
PARITY is displayed.
9.
Press the UNITS key…
The current setting is displayed. Use the
ZERO key to toggle between the three
choices: EVEN, ODD, NONE.
Step-by-Step
Instructions for
CONFIG Mode
Press the ZERO key to
scroll through lists of
selections.
Press the UNITS key
to make a selection
Tip: Quickly and easily
view current scale
configuration directly
from the front panel
without opening the
scale or setting
switches as follows:
During the display
segment test on
power-up, press the
UNITS key. The
display will prompt
ABORT followed
by BAUD. Press the
ZERO key to scroll
through the choices, or
press the UNITS
key to view a current
scale configuration.
When you are done,
press the ZERO key
until DONE is dis-
played. Press the
UNITS key to return to
the normal weighing
mode.