Salter Brecknell 7680 User Manual
Page 17
Model 7600 Family PWC User’s Manual
17
RNG ON
Choosing this function activates the
multi-ranging function of the scale.
Display returns to higher resolution
mode only after returning to a stable
zero (0.00). For TYPE APPROVED
applications.
RNG OFF Choosing this function places the
scale in the high resolution through
capacity of the scale. For NON-
TYPE APPROVED applications only.
INT ON
Choosing this function activates the
multi-interval function of the scale.
Display returns to higher resolution
mode immediately at multi-ranging
weight value. For TYPE APPROVED
applications.
The NCI 7600 bench scales allow calibration
using less than full capacity weights. Below are
the alternative weights that can be used to
calibrate your scale for its designated capacity.
Alternative Span
Capacity
Calibration Weights
lbs
70
10/50/70
100
10/50/100
150
10/50/150
kgs
30
10/20/30
50
10/25/50
75
10/50/75
Table 5
Alternate Span
Calibration Points
Table 6