Configuration mode – Salter Brecknell 7680 User Manual
Page 21

Model 7600 Family PWC User’s Manual
21
18. Press the UNITS key to stop the test.
19. When you are finished with the test, press
the ZERO key, until DONE is displayed.
Press the UNITS key, or place Switch 1 back
to normal mode to return to normal weighing
mode.
The Configuration (CONFIG) mode menu lets
you configure your scale to your specific applica-
tion needs. The items you can configure are as
follows:
Filter (FILTER) – Choose from FLTR ON OR
FLTR OFF. Default is FLTR ON. In a stable,
vibration free location, the FLTR OFF setting
could be used if quicker display response is
desired.
Baud (BAUD) – Choose one of the following
baud rates: 1200, 2400, 4800, 9600, and 19200.
Default is 9600.
Parity (PARITY) – Choose from: NONE, EVEN,
or ODD. Default is EVEN.
Protocol (Prot) – Choose communication
protocol: NCI STD for standard NCI protocol, NCI
SMA for Scale Manufacturers’ Association
Standard for Scale Serial Communications,
AS350d for Detecto emulation, or PS6L for
Mettler emulation. Default is NCI STD.
Configuration Mode
Configuration (CONFIG)
Mode