Salter Brecknell 7840 User Manual
Page 25

Model 7800 Family Weight Classifiers User’s Manual
25
Step-by-Step
Insutructions for CAL
Mode
CAPACITY (100.02, 150.05, 250.05, 300.1, etc.)
– Select the capacity of the scale.
Follow these steps to calibrate the scale. Refer to
Figure 3 on Page 18.
1. From the DIAG display, press the ZERO key
until CAL is displayed, or from the normal
weighing mode, move Switch 1 to the Menu
mode or OPEN position. Press the ZERO
key until CAL is displayed.
2. Press the TEST key...
LBS (lb) or 1000G (kg) is displayed.
3. Press the ZERO key to toggle between the
choices. When the choice you want is
displayed, press the TEST key to accept...
The choice is accepted.
If LBS (lb) was selected, the scale will
display CLASS.
If 1000G (kg) was selected, scale
displays the present capacity setting.
Proceed to Step 5.
4. Press the ZERO key to toggle between
SCALE and CLASS. When the choice you
want is displayed, press the TEST key...
That choice is accepted and a scale
capacity is displayed.
Example: 100.02
If a different capacity selection is desired,
press the ZERO key to scroll through the
choices.