beautypg.com

Counting procedure – Salter Brecknell C3255 User Manual

Page 6

background image

1000 Armstrong Drive. Fairmont, Minnesota 56031 Tel: 507-238-8702 Fax: 507-238-8271 e-mail:

[email protected]

For technical support contact us at 1-800- 458-7062 or fax us at 1-800-368-2042

Page 6 of 18

COUNTING PROCEDURE

The C3255 check weigher includes a simple counting function. The minimum sample size weight

required is 1/5d of scales capacity and resolution.

*Important note, for accurate counting it is suggested to use the largest sample weight as possible.

1. Make sure all weight is removed from platform.

2.

If tare is required, press the

Tare

key prior to sampling to tare out the weight of a empty

container.

3. Press

MODE

key to enter into counting mode, the display will show:

4. There are four pre-defined samples sizes available in the C3255. They are 10 pieces, 25 pieces,

50 pieces and 100 pieces. Press

SET

key to scroll to the desired sampling quantity.

5. Once the desired sampling size is chosen, add the appropriate # of pieces onto the platform or

into the empty (tared) container.

* NOTE:

If no weight is placed on the scale, and you exit the counting function by pressing the

MODE

key, the scale will display an invalid # of pieces.

6. With the sample weight on the scale, the display will flash for 3-5 seconds.

7. Once the sample weight is stable, the stable enunciator will light and the scale will show the

value of the sample weight.

•••• NOTE:

If the displayed value of pieces does not equal the sample chosen, repeat steps 1-7

and chose a higher sample size value.

8. Press the

MODE

key to exit counting and return to normal weighing mode. Your sample value

will be saved and stored until you store a new sample size is stored.

NOTE:

The counting feature on the Model C3255 is NON TYPE approved.