COUNTING PROCEDURE
The C3255 check weigher includes a simple counting function. The minimum sample size weight
required is 1/5d of scales capacity and resolution.
*Important note, for accurate counting it is suggested to use the largest sample weight as possible.
1. Make sure all weight is removed from platform.
2.
If tare is required, press the
Tare
key prior to sampling to tare out the weight of a empty
container.
3. Press
MODE
key to enter into counting mode, the display will show:
4. There are four pre-defined samples sizes available in the C3255. They are 10 pieces, 25 pieces,
50 pieces and 100 pieces. Press
SET
key to scroll to the desired sampling quantity.
5. Once the desired sampling size is chosen, add the appropriate # of pieces onto the platform or
into the empty (tared) container.
* NOTE:
If no weight is placed on the scale, and you exit the counting function by pressing the
MODE
key, the scale will display an invalid # of pieces.
6. With the sample weight on the scale, the display will flash for 3-5 seconds.
7. Once the sample weight is stable, the stable enunciator will light and the scale will show the
value of the sample weight.
•••• NOTE:
If the displayed value of pieces does not equal the sample chosen, repeat steps 1-7
and chose a higher sample size value.
8. Press the
MODE
key to exit counting and return to normal weighing mode. Your sample value
will be saved and stored until you store a new sample size is stored.
NOTE: