beautypg.com

Error messages – Salter Brecknell C3255 User Manual

Page 18

background image

1000 Armstrong Drive. Fairmont, Minnesota 56031 Tel: 507-238-8702 Fax: 507-238-8271 e-mail:

[email protected]

For technical support contact us at 1-800- 458-7062 or fax us at 1-800-368-2042

Page 18 of 18

ERROR MESSAGES

1. Low Battery -

If this message is displayed, it indicates that

the battery needs to be replaced.

Solution:

Replace the battery or plug in the

AC adaptor for operations.

2. Below Zero -

The scale senses a weight value that is less

than the allowable limit.

Solution:

Re-power on the scale again. If

the message continues, the operator should

ask the maintenance men to check the

scale

.

3. Over Zero -

This message indicates that operator have

too much weight on the scale when operator

turned the scale on.

Solution:

Remove the excess weight from

the scale platform and turn the scale off and

then back on. If the scale continues to

display this message, call for service.

4. Overload -

If the weighting capacity exceeds the

maximum capacity of scale, the display will

show the right message.

Solution:

Remove the weight from scale

platform right away.

5. Power on zero count over calibration zero

+10%.

Solution:

Turn the scale off and then back

on.

6. Power on zero count under calibration zero -

10%.

Solution:

Turn the scale off and then back

on.