Table 2 - Division Setting Table

When setting up the Mode selection, each mode (example CS_15) has 4 separate division setting

which will give you the selection capacity and resolution for KG and LBS. Choose the correct

setting below for your needs.

Mode

Selectable

Division

Setting

Capacity and

Resolution KG

# of divisions Capacity and

Resolution LB

# of divisions

Accuracy

CS_6

6.0020 kg

6 x 0.002 kg

3,000 d

N/A

N/A

N/A

6.0010 kg

6 x 0.001 kg

6,000 d

N/A

N/A

N/A

6.0005 kg

6 x 0.0005 kg

12,000 d

N/A

N/A

N/A

6.0002 kg

6 x 0.0002 kg

30,000 d

N/A

N/A

N/A

CS_15

15.0050 kg

15 x 0.005 kg

3,000 d

30 x 0.01 lb

3,000 d

+ / - 1 d

12.0020 kg

15 x 0.002 kg

7,500 d

30 x 0.005lb

6,000 d

N/A

15.0010 kg

15 x 0.001 kg

15,000 d

N/A

N/A

15.0005kg

15 x 0.0005 kg

30,000 d

N/A

N/A

CS_30

30.010 kg

30 x 0.01 kg

3,000 d

60 x 0.02 lb

3,000 d

+ / - 1 d

30.005 kg

30 x 0.005 kg

6,000 d

60 x 0.01 lb

N/A

30.002 kg

30 x 0.002 kg

15,000 d

N/A

N/A

30.001kg

30 x 0.001 kb

30,000 d

N/A

N/A

CS_60

60.020 kg

60 x 0.02 kg

3,000 d

150 x 0.05 lb

3,000 d

+ / - 1 d

60.010 kg

60 x 0.01 kg

6,000 d

150 x 0.02 lb

N/A

60.005 kg

60 x 0.005 kg

12,000 d

N/A

N/A

N/A

60.002 kg

60 x 0.002 kg

30,000d

N/A

N/A

N/A

CS_150

150.050 kg

150 x 0.05 kg

3000 d

300 x 0.1 lb

3,000 d

+ / - 1 d

120.020 kg

120 x 0.02 kg

6,000 d

300 x 0.05 lb

6,000 d

N/A

150.010 kg

150 x 0.01 kg

15,000 d

N/A

N/A

N/A

150.005 kg

150 x 0.005 kg

30,000 d

N/A

N/A

N/A

CS_300

300.10 kg

N/A

N/A

300.05 kg

N/A

N/A

300.02 kg

N/A

N/A

300.01 kg

N/A

N/A

* Grey Shaded areas indicate capacities only available for Model 3255.

** Bold and shaded areas indicate NTEP approved capacities and resolutions only