beautypg.com

Side view, Front view, General information – Qmark IUH - Industrial Unit Heater User Manual

Page 2: Specifications

background image

* Factory wired for 1 Phase - Field convertible to 3 Phase.

** Factory wired for 3 Phase - Field convertible to 1 Phase.

*** 48 in. (1219) for 45 deg. to vertical downward.

Dim.

Heater Size

inches (mm)

5 - 7.5 KW

10 - 20 KW

25 - 30 KW

A

14 (354)

18 (457)

26 (660)

B

12

1

/

2

(317)

18 (457)

24 (609)

C

12

1

/

2

(317)

17

1

/

2

(444)

23

1

/

8

(587)

D

5

1

/

2

(139)

9

15

/

32

(240)

9

15

/

32

(240)

E

13 (330)

#

20 (508)

F

1

3

/

4

(44)

2 (51)

2 (51)

G

1

3

/

8

(35)

2

1

/

2

(63)

2

3

/

4

(70)

H

1

1

/

2

(38)

2

1

/

4

(57)

2

1

/

4

(57)

J

1

/

2

(12.7)

3

/

4

(19.1)

1 (25.4)

3

/

4

(19.7)

1 (25.4)

1

1

/

2

(38)

1 (25.4)

1 (25.4)

K

1

/

2

(12.7)

1

1

/

4

(32)

1

1

/

2

(38)

1

1

/

2

(38)

2 (50.8)

Wiring

60 in

3

105 in

3

288 in

3

Compartment

(968 cm

3

)

(1720 cm

3

)

(4720 cm

3

)

Volume

SIDE VIEW

MOUNTING

LOCATION

MINIMUM

TO WALL

FRONT VIEW

E

D

C

H

J

K

G

F

1"

B

A

GENERAL INFORMATION

Automatic Fan Delay: All models incorporate an automatic fan

delay. When the thermostat calls for heat, fan action is delayed

momentarily until the heating element is warm. When the ther-

mostat is satisfied, the fan continues to operate until the heating

element is cool. This action prevents circulation of cold air, and

avoids exposing unit to residual heat, thus providing higher com-

fort level and prolonged element life.

Optional Controls and Accessories: The following controls and

accessories are available from your electrical distributor.

Catalog

Number

Description

CWB-1

Combination wall brackets for 2.5 kw thru 15 kw units.

CWB-2

Same as above but for 20 kw thru 50 kw units

TA-1

Single pole thermostat kit 60 to 120° F temp. range for

field installation in all units.

DS-30

3-pole power disconnect switch kit for field

installation on unit heaters rated 30 amps or less.

DS-63

3-pole power disconnect switch kit for field installation

on unit heaters 10kw and above rated at 30 to 63 amps.

2

Specifications

Mounting Height

Center of Heater

Wattage

Heater

Wiring

ft. (mm)

Air Throw

to Wall

Ship Wt.

Model No.

(KW)

Btu/Hr.

Voltage

Phase

Min.

Max.

ft. (mm)

inches (mm)

lb. (kg)

UH520

UH524

UH534

UH548

UH560

UH720

UH724

UH727

UH734

UH748

UH760

UH1020

UH1024

UH1027

UH1034

UH1048

UH1060

UH1520

UH1524

UH1527

UH1534

UH1548

UH1560

UH2034

UH2048

UH2060

UH2548

UH2560

UH3048

UH3060

208

240

347

480

600

208

240

277

347

480

600

208

240

277

347

480

600

208

240

277

347

480

600

347

480

600

480

600

480

600

1*

1*

1

3

3

1*

1*

1

1

3**

3

1*

1*

1

1

3**

3

3**

3**

1

1

3**

3

1

3**

3
3
3

5.0

7.5

10.0

15.0

20.0

25.0

30.0

17,065

25,598

34,130

51,195

68,260

85,325

102,390

6 (1828)

6 (1828)

6 (1828)

6 (1828)

6 (1828)

6 (1828)

6 (1828)

8 (2486)

8 (2436)

9 (2743)

10 (3048)

11 (3352)

15 (4572)

15 (4572)

18 (5486)

20 (6096)

20 (6096)

28 (8534)

32 (9753)

34 (10360)

38 (11582)

13 (333)***

13 (333)***

13 (333)

13 (333)

16 (406)

20 (508)

20 (508)

30 (13.60)

30 (13.60)

72 (32.66)

78 (35.38)

78 (35.38)

136 (61.69)

142 (64.40)

# 13” (330 cm) for 10KW, 12.5KW, and 15KW; 16” (40.5 cm) for 20KW heaters