BIOS POST Error Codes and Messages
SR870BN4 Error Reference Guide
Revision
1.0
16
Error Code
Error Message
Pause on Boot
Recommended User Action
8504
Persistent Single-bit Error
Detected Row1. Row 1 mapped
out
Yes
Verify the affected memory and
replace with correct memory.
8505
Persistent Single-bit Error
Detected Row2. Row 2 mapped
out
Yes
Verify the affected memory and
replace with correct memory.
8506
Persistent Single-bit Error
Detected Row3. Row 3 mapped
out
Yes
Verify the affected memory and
replace with correct memory.
8507
Persistent Single-bit Error
Detected Row4. Row 4 mapped
out
Yes
Verify the affected memory and
replace with correct memory.
8508
Memory Mismatch detected Row1.
Row 1 mapped out
Yes
Verify the affected memory and
replace with like memory.
8509
Memory Mismatch detected Row2.
Row 2 mapped out
Yes
Verify the affected memory and
replace with like memory.
850A
Memory Mismatch detected Row3.
Row 3 mapped out
Yes
Verify the affected memory and
replace with like memory.
850B
Memory Mismatch detected Row4.
Row 4 mapped out
Yes
Verify the affected memory and
replace with like memory.
850C
DIMM1, memory board 1
defective.
Yes
Verify the affected memory and
replace with good memory.
850D
DIMM2, memory board 1
defective.
Yes
Verify the affected memory and
replace with good memory.
850E
DIMM3, memory board 1
defective.
Yes
Verify the affected memory and
replace with good memory.
850F
DIMM4, memory board 1
defective.
Yes
Verify the affected memory and
replace with good memory.
8510
DIMM5, memory board 1
defective.
Yes
Verify the affected memory and
replace with good memory.
8511
DIMM6, memory board 1
defective.
Yes
Verify the affected memory and
replace with good memory.
8512
DIMM7, memory board 1
defective.
Yes
Verify the affected memory and
replace with good memory.
8513
DIMM8, memory board 1
defective.
Yes
Verify the affected memory and
replace with good memory.
8514
DIMM1, memory board 2
defective.
Yes
Verify the affected memory and
replace with good memory.
8515
DIMM2, memory board 2
defective.
Yes
Verify the affected memory and
replace with good memory.
8516
DIMM3, memory board 2
defective.
Yes
Verify the affected memory and
replace with good memory.
8517
DIMM4, memory board 2
defective.
Yes
Verify the affected memory and
replace with good memory.
8518
DIMM5, memory board 2
defective.
Yes
Verify the affected memory and
replace with good memory.
8519
DIMM6, memory board 2
defective.
Yes
Verify the affected memory and
replace with good memory.
851A
DIMM7, memory board 2
defective.
Yes
Verify the affected memory and
replace with good memory.
851B
DIMM8, memory board 2
defective.
Yes
Verify the affected memory and
replace with good memory.