beautypg.com

Dell PowerEdge 2900 User Manual

Page 25

background image

About Your System

25

E2112

Mem Spare DIMM

##

The system BIOS has spared the
memory because it has
determined that the memory had
too many errors. "## & ##"
represents the DIMM pair
implicated by the BIOS.

See "Troubleshooting System
Memory" on page 124.

E2113

Mem Mirror DIMM

## & ##

They system BIOS has disabled
memory mirroring because it has
determined that one half of the
mirror has had too many errors.
"## & ##" represents the
DIMM pair implicated by the
BIOS.

See "Troubleshooting System
Memory" on page 124.

E2118

Fatal NB Mem CRC

One of the connections in the

Fully Buffered DIMM (

FBD)

memory subsystem link on the
Northbound side has failed.

See "Troubleshooting System
Memory" on page 124.

E2119

Fatal SB Mem CRC

One of the connections in the
FBD memory subsystem link on
the Southbound side has failed.

See "Troubleshooting System
Memory" on page 124.

I1910

Intrusion

System cover has been removed.

Information only.

I1911

>3 ERRs Chk Log

LCD overflow message.

A maximum of three error
messages can display sequentially
on the LCD. The fourth message
displays as the standard overflow
message.

Check the SEL for details on the
events.

I1912

SEL Full

System Event Log is full of
events, and is unable to log any
more events.

Clear the log by deleting event
entries.

W1228

ROMB Batt < 24hr

Warns predictively that the RAID
battery has less than 24 hours of
charge left.

Replace RAID battery. See
"Replacing the SAS RAID
Controller Daughter Card
Battery" on page 96.

NOTE:

For the full name of an abbreviation or acronym used in this table, see the "Glossary" on page 169.

Table 1-6.

LCD Status Messages (continued)

Code

Text

Causes

Corrective Actions