Event log messages, Offload iscsi (ois) driver – Dell Broadcom NetXtreme Family of Adapters User Manual
Page 98

iSCSI Protocol: Broadcom NetXtreme II® Network Adapter User Guide
file:///C|/Users/Nalina_N_S/Documents/NetXtremeII/English/iscsi.htm[9/5/2014 3:45:06 PM]
Event Log Messages
lists the offload iSCSI driver event log messages.
Offload iSCSI (OIS) Driver
Table 5: Offload iSCSI (OIS) Driver Event Log Messages
Message
Number Severity
Message
1
Error
Initiator failed to connect to the target. Target IP address and TCP Port number are given in dump
data.
2
Error
The initiator could not allocate resources for an iSCSI session.
3
Error
Maximum command sequence number is not serially greater than expected command sequence
number in login response. Dump data contains Expected Command Sequence number followed by
Maximum Command Sequence number.
4
Error
MaxBurstLength is not serially greater than FirstBurstLength. Dump data contains FirstBurstLength
followed by MaxBurstLength.
5
Error
Failed to setup initiator portal. Error status is given in the dump data.
6
Error
The initiator could not allocate resources for an iSCSI connection
7
Error
The initiator could not send an iSCSI PDU. Error status is given in the dump data.
8
Error
Target or discovery service did not respond in time for an iSCSI request sent by the initiator. iSCSI
Function code is given in the dump data. For details about iSCSI Function code please refer to iSCSI
User's Guide.
9
Error
Target did not respond in time for a SCSI request. The CDB is given in the dump data.
10
Error
Login request failed. The login response packet is given in the dump data.
11
Error
Target returned an invalid login response packet. The login response packet is given in the dump
data.
12
Error
Target provided invalid data for login redirect. Dump data contains the data returned by the target.
13
Error
Target offered an unknown AuthMethod. Dump data contains the data returned by the target.
14
Error
Target offered an unknown digest algorithm for CHAP. Dump data contains the data returned by the
target.
15
Error
CHAP challenge given by the target contains invalid characters. Dump data contains the challenge
given.
16
Error
An invalid key was received during CHAP negotiation. The key=value pair is given in the dump data.
17
Error
CHAP Response given by the target did not match the expected one. Dump data contains the CHAP
response.
18
Error
Header Digest is required by the initiator, but target did not offer it.
19
Error
Data Digest is required by the initiator, but target did not offer it.
20
Error
Connection to the target was lost. The initiator will attempt to retry the connection.
21
Error
Data Segment Length given in the header exceeds MaxRecvDataSegmentLength declared by the
target.
22
Error
Header digest error was detected for the given PDU. Dump data contains the header and digest.
23
Error
Target sent an invalid iSCSI PDU. Dump data contains the entire iSCSI header.
24
Error
Target sent an iSCSI PDU with an invalid opcode. Dump data contains the entire iSCSI header.
25
Error
Data digest error was detected. Dump data contains the calculated checksum followed by the given
checksum.
26
Error
Target trying to send more data than requested by the initiator.
27
Error
Initiator could not find a match for the initiator task tag in the received PDU. Dump data contains the
entire iSCSI header.
28
Error
Initiator received an invalid R2T packet. Dump data contains the entire iSCSI header.
29
Error
Target rejected an iSCSI PDU sent by the initiator. Dump data contains the rejected PDU.
30
Error
Initiator could not allocate a work item for processing a request.
31
Error
Initiator could not allocate resource for processing a request.