beautypg.com

Go to step 14 if an error message, Indicated, go to step 14 – Dell DX6012S User Manual

Page 128

background image

138

Troubleshooting Your System

5 Turn off the system and attached peripherals, and disconnect the system

from the electrical outlet.

6 Open the system. See "Opening the System" on page 70.
7 Remove the cooling shroud. See "Removing the Cooling Shroud" on

page 72.

8 Check the memory channels and ensure that they are populated correctly.

See "General Memory Module Installation Guidelines" on page 84.

9 Reseat the memory modules in their sockets. See "Installing Memory

Modules" on page 87.

10 Replace the cooling shroud. See "Installing the Cooling Shroud" on

page 73.

11 Close the system. See "Closing the System" on page 71.
12 Reconnect the system to its electrical outlet, and turn on the system

and attached peripherals.

13 Enter the System Setup program and check the system memory setting.

See "Memory Settings Screen" on page 49.

If the problem is not resolved, proceed with the next step.

14 Turn off the system and attached peripherals, and disconnect the system

from the power source.

15 Open the system. See "Opening the System" on page 70.
16 If a diagnostic test or error message indicates a specific memory module

as faulty, swap or replace the module.

17 To troubleshoot an unspecified faulty memory module, replace the

memory module in the first DIMM socket with a module of the same type
and capacity. See "Installing Memory Modules" on page 87.

18 Close the system. See "Closing the System" on page 71.
19 Reconnect the system to its electrical outlet, and turn on the system and

attached peripherals.

20 As the system boots, observe any error message that appears and the

diagnostic indicators on the front of the system.

21 If the memory problem is still indicated, repeat step 14 through step 20 for

each memory module installed.

book.book Page 138 Friday, February 26, 2010 11:22 AM