TABLE 6

SAN I/O Module Specifications

Dimension

Measurements

Height

1.27 in (32.48 mm)

Width

10.74 in (272.75 mm)

Depth

12.09 in (307.24 mm)

Weight

4.65 (2.10 kg) — without media

TABLE 7

Environmental Requirements

Condition

Operating

Non-operating

Temperature

32°F to 104°F (0°C to 40°C)

-4°F to 158°F (-20°C to 70°C)

Humidity

10% to 90%, non-condensing at

84.2°F (29°C)

5% to 95%, non-condensing at

100.4 °F (38°C)

Altitude

Up to 10,000 ft (3,048 m)

35,000 ft (10,668 m)

Shock

20 G for 6 ms

50G with velocity change of 4216
mm/sec squared

Vibration

0.4 G at 5-500 Hz
for 60 minutes

0.5 G at 2-200 Hz for 15 minutes

Air flow

86 °F (30°C) Ambient: Approx. 3CFM
104°F (40°C) Ambient: Approx.
9CFM

None required