Weight and physical dimensions, Facility requirements – Dell POWEREDGE M1000E User Manual
Page 36
26
M5424 SAN I/O Module Hardware Reference Manual
53-1001082-01
Weight and physical dimensions
A
Weight and physical dimensions
lists the weight and physical dimensions of the SAN I/O Module.
Facility requirements
The information in
shows the operating and non-operating limitations of the Brocade
M5424 Fibre Channel SAN I/O Module SAN I/O Module.
TABLE 6
SAN I/O Module Specifications
Dimension
Measurements
Height
1.27 in (32.48 mm)
Width
10.74 in (272.75 mm)
Depth
12.09 in (307.24 mm)
Weight
4.65 (2.10 kg) — without media
TABLE 7
Environmental Requirements
Condition
Operating
Non-operating
Temperature
32°F to 104°F (0°C to 40°C)
-4°F to 158°F (-20°C to 70°C)
Humidity
10% to 90%, non-condensing at
84.2°F (29°C)
5% to 95%, non-condensing at
100.4 °F (38°C)
Altitude
Up to 10,000 ft (3,048 m)
35,000 ft (10,668 m)
Shock
20 G for 6 ms
50G with velocity change of 4216
mm/sec squared
Vibration
0.4 G at 5-500 Hz
for 60 minutes
0.5 G at 2-200 Hz for 15 minutes
Air flow
86 °F (30°C) Ambient: Approx. 3CFM
104°F (40°C) Ambient: Approx.
9CFM
None required