beautypg.com

Cabling guidelines – Dell POWEREDGE M1000E User Manual

Page 18

background image

8

M5424 SAN I/O Module Hardware Reference Manual

53-1001082-01

Cabling guidelines

1

5. Be sure that you have taken the necessary precautions for electrostatic sensitivity; then break

the seal warning.

6. Slide the SAN I/O Module out of the antistatic sleeve and inspect it carefully for any obvious

defects or shipping damage.

7. For complete instructions to install the SAN I/O Module into the Blade Server Enclosure, refer

to the section on installing an I/O module in the Blade Server Enclosure Hardware Owner’s
Manual
.

Cabling guidelines

After modifying the SAN I/O Module’s IP address and domain name (if SAN I/O Module is in Fabric
OS Native mode), we recommend that you cable all external ports to fabric connections before
bringing the SAN I/O Module online. Refer to

Chapter 2, “Configuring the SAN I/O Module,”

for

steps on modifying the IP address.

Begin by cabling ports 17, 18, 19, 20, 21, 22, 23, and 0. Ports 17 and 18 are licensed at the
factory as part of Dynamic Ports On Demand (DPOD). By cabling these ports first, you will not need
to move licenses to other ports you may have cabled.