System messages appear on the screen to notify you of a possible problem with the system.

Table 2

-5

lists the system messages that can occur and the

probable cause and corrective action for each message.

 

Table 2-5. System Messages 

NOTE:

If you receive a system message that is not listed in

Table 2

-5

, check the documentation for the application that is running when the message

appears or the operating system's documentation for an explanation of the message and recommended action.

 

Message

 

Causes

 

Corrective Actions

A filename cannot contain any of the following characters:

\ / : * ? " < > |

 

Do not use these characters in filenames.

A required .DLL file was not found

The application that you are trying to
open is missing an essential file.

Remove and then reinstall the application.

See the application's documentation for
installation instructions.

Alert! CPU fan not detected

The processor cooling fan is faulty or the
fan assembly is not installed correctly.

Ensure that the processor cooling shroud is
properly installed. See "

Cooling Fans

" in

"Installing System Options."

Alert! Rear fan failure

Cooling fan is faulty or the fan assembly
is not installed correctly.

See "

Cooling Fans

" in "Installing System

Options."

Alert! Previous reboot was due to voltage regulator failure

 

See "

Getting Help

."

 

Alert! System battery voltage is low

 

Replace the battery. See "

Troubleshooting

the System Battery

" in "Troubleshooting Your

System."

Alert! Unable to initialize all installed memory

One or more memory modules might be
faulty or improperly seated.

See "

Troubleshooting System Memory

" and

"Troubleshooting Your System."

If the problem persists, see "

Getting Help

."

System halted! Mixing ECC and non-ECC DIMMs is not

supported on this platform

 

See "

Troubleshooting System Memory

" and

"Troubleshooting Your System."

If the problem persists, see "

Getting Help

."

Alert! Cover was previously removed.

The system was opened.

Information only. To reset the chassis
intrusion switch, see "Using the System
Setup Program" in your User's Guide.

Alert! CPU 0 fan failure.

The processor cooling fan is faulty or the
fan assembly is not installed correctly.

Ensure that the processor cooling shroud is
properly installed. See "

Cooling Fans

" in

"Installing System Options."

Alert! Card-cage fan failure

A card-cage fan is not detected during
POST. The system will halt at the
/ prompt even if Keyboard
Errors Report
option is disabled in the
System Setup program.

See "

Cooling Fans

" in "Installing System

Options."

Alert! Error initializing PCI Express slot n (or bridge).

The system encountered a problem while
trying to configure a PCIe expansion card

See "

Troubleshooting Expansion Cards

" in

"Troubleshooting Your System."

Alert! OS Install Mode enabled. Amount of available memory

limited to 256MB

The OS Install Mode option in the
System Setup program is set to On. This
limits the amount of available memory to
256 MB because some operating systems
will not complete installation with more
than 2 GB of system memory.

After the operating system is installed, enter
the System Setup program and set the OS
Install Mode
option to Off. See your User's
Guide
for details.

Alert! Previous fan failure.

The fan caused errors the last time the
system was used.

Ensure that nothing is blocking the airflow
vents and that all fans are properly installed
and operating correctly.

Alert! Previous attempts at booting this system have failed

at checkpoint [nnnn]. For help in resolving this problem,

please note this checkpoint and contact Dell Technical

Support

The system failed to complete the boot
routine three consecutive times for the
same error.

See "

Getting Help

."

Alert! Previous Processor Thermal Failure

The processor overheated the last time
the system was used.

Ensure that nothing is blocking the airflow
vents and that all fans are properly installed
and operating correctly. Also, ensure that the
processor heat sink is properly installed. See
"

Microprocessor

" in "Installing System

Options."

Alert! Previous Shutdown Due to Thermal Event

The processor or hard drive overheated
the last time the system was used.

Ensure that nothing is blocking the airflow
vents and that all fans are working correctly.
Also, ensure that the processor heat sink is
properly installed. See "

Microprocessor

" in

"Installing System Options."

Alert! Uncorrectable Memory Error Previously Detected

One or more memory modules might be
improperly seated or faulty, or the system
board may be faulty.

See "

Troubleshooting System Memory

" and

"Troubleshooting Your System."

If the problem persists, see "

Getting Help

."

Attachment failed to respond

The diskette or hard-drive controller
cannot send data to the associated drive.

See "

Troubleshooting a Diskette Drive

,"

"

Troubleshooting SATA Hard Drives

," or

"

Troubleshooting SCSI Hard Drives

" in

"Troubleshooting Your System."