Canon GM-1000 User Manual
Page 64

CANON Digital Galvano Scanner System GM-1000 Series
Users Manual 1.20
64
Analog monitor output connector
Connector model number
Connector Model
No.
Manufacturer
Board side
XG4C-1034
OMRON
Cable side
XG4M-1030-T
OMRON
Connector pin assignment
Pin No.
Monitor Board for
Evaluation
Signal Name
Signal Description
1
A1
Axis 1 current command value
2
A2
Axis 1 analog monitor 1 (Monitor item switching)
3
A3
Axis 1 analog monitor 2 (Monitor item switching)
4
A4
Axis 1 analog monitor 3 (Monitor item switching)
5
A5
Axis 2 current command value
6
A6
Axis 2 analog monitor 1 (Monitor item switching)
7
A7
Axis 2 analog monitor 2 (Monitor item switching)
8
A8
Axis 2 analog monitor 3 (Monitor item switching)
9 A9
Analog
GND
10 A10
Analog
GND
The controller has three monitor terminals for each of the two axes to check the operation status.
The output signal contents can be changed and the output magnification can also be changed.
(For details, see 5.2. “Analog Monitor Output Selecting”)