beautypg.com

Cabletron Systems DLE22-MA User Manual

Page 190

background image

Appendix C: Mode Switch Bank Settings and Optional Installations

C-2

DLE22-MA, DLE32-MA, DLE23-MA and DLE33-MA User’s Guide

Figure C-1 shows the location of the mode switches and the switch
settings for normal operation.

Figure C-1

DLE2X-MA and DLE3X-MA Mode Switch

Location/Component Layout

Switch definitions and positions are as follows:

Switches 1 through 4 – For Digital Equipment Corporation use only.

Switch 5 – COM Port Autobaud. The default (OFF) position enables
Autobaud sensing on the COM port for Local Management sessions.
Changing the switch to the ON position disables Autobaud sensing
and sets the COM port to 9600 baud for Local Management sessions.

Switch 6 – Forced BootP. Changing the position of this switch (i.e.,
moving the switch from one position to the other) clears download
information from NVRAM and forces the DLE2X-MA and
DLE3X-MA to download a new image file from a BootP server after
power to the chassis is restored, or the RESET button is pressed.

Flash

DRAM

MODE SWITCH BANK

1

2

3

4

5

6

7

8

OFF

ON

LKG-10976-98F