Lim status leds, Infiniband port leds, Lim status leds infiniband port leds – Cisco SFS 7008 User Manual
Page 75: Infiniband, Location, Interpreting the lim status leds

75
LIM Status LEDs
Location
The LIM Status LED is located at the far left of each LIM card (if you are facing the back of the
chassis). Refer to
Figure 5-5
for a complete diagram of the back panel of the chassis.
Figure 5-8: LIM Status Indicator LEDs
Interpreting the LIM Status LEDs
InfiniBand Port LEDs
The InfiniBand LED represents the logical link and the logical link activity.
Table 5-13: Interpreting the Chassis ID Status LEDs (see
)
Color
State
Indication
Green/Yellow
off
No module power, or LED failure.
Green
solid on
Chassis ID module is running with no errors detected.
Green
off
No power to the Chassis ID module, LED failure, or yellow
LED is On.
Yellow
solid on
Failure of the Chassis ID module. Operator attention required.
The “!” label indicates a failure.
Yellow
blinking
Identify a Chassis ID module. Assists in identifying a
particular Field Replaceable Unit on the chassis.
This state is initiated by the user.
This LED can be initiated manually by using the diag LED test.
Refer to the Command Line Reference Guide for more
information.
LIM Status Indicator
Table 5-14: Interpreting the LIM Status LED
Color
State
Indication
Green and
Yellow
off
No module power, or LED failure.
Green
solid on
Line Interface module is running with no errors
detected.
Green
off
No power to the Line Interface module, LED
failure, or yellow LED is On.
Yellow
solid on
Failure of the Line Interface module. Operator
attention required.
The “!” label indicates a failure.