Fabric Controller LEDs
Each Fabric Module has two sets of LED indicators.
•
The two LEDs (green or yellow) are the module status indicators (
•
The single LED (green only) indicates whether of not the module is the active system master
(
).
Location
Refer to
Figure 5-1
to view the front panel of the chassis.
Figure 5-4: Locate Fabric Controller LEDs
Interpreting the Fabric Controller LEDs
Module
Status
Active System Master Indicator
Table 5-5: Interpreting the Fabric Controller’s Module Status LEDs (see
Figure 5-1
and
)
Color
State
Indication
Green over
Yellow
off
No system power, or LED failure.
Green
solid on
System running with no errors detected.
Green
off
No power to the fabric controller, LED failure, or
yellow LED is On.
Yellow
off
No failure on the fabric controller.
Yellow
solid on
Module error detected. Operator intervention
required.
Yellow
blinking
Identify. Assists in identifying a particular Field
Replaceable Unit on the chassis.
This state is initiated by the user.
This LED can be initiated manually by using the
diag LED test. Refer to the Command Line
Reference Guide for more information.
Table 5-6: Interpreting the Fabric Controller’s Master Status LED (see
Color
State
Indication
Active Master Status Indicator
Green
on
This module is currently the system master.
Note that only fabric modules in one of the two
core slots can become master.
Green
off
This module is not the active system master.
Note that only fabric modules in one of the two
core slots can become master.