Displaying hardware errors – Cisco SFS 7008 User Manual
Page 99
99
Displaying Hardware Errors
To display POST results, non-fatal errors that can are recovered, informational logging (such as
firmware updates), and hardware errors:
1. Use the more syslog:hwif_log command to locate the:
/topspin/log/hwif_log
Example of output without errors
You can also view POST error codes with the show diagnostic post command. This command displays
the results of each POST that executed at power-on.
Example
Topspin-270> enable
Topspin-270# more syslog:hwif_log
Thu Mar 4 10:57:49 2004: POST: SEEPROM: PASSED
Thu Mar 4 10:57:49 2004: POST: FPGA: PASSED
Thu Mar 4 10:57:49 2004: POST: SUMMIT: PASSED
Thu Mar 4 10:57:50 2004: POST: RTC: PASSED
Thu Mar 4 10:57:54 2004: POST: FAN: PASSED
Thu Mar 4 10:57:54 2004: card_startup.x : card is starting up
Thu Mar 4 10:57:54 2004: Anafa2Init: a2update set to IGNORE
Thu Mar 4 10:58:16 2004: Anafa2 POST: firmware check PASSED
Thu Mar 4 19:01:55 2004: POST: SEEPROM: PASSED
Thu Mar 4 19:01:55 2004: POST: FPGA: PASSED
Thu Mar 4 19:01:55 2004: POST: SUMMIT: PASSED
Thu Mar 4 19:01:56 2004: POST: RTC: PASSED
Thu Mar 4 19:02:00 2004: POST: FAN: PASSED
Thu Mar 4 19:02:00 2004: card_startup.x : card is starting up
Thu Mar 4 19:02:00 2004: Anafa2Init: a2update set to IGNORE
Topspin-270# show diagnostic post
================================================================================
Post Status
================================================================================
fru-slot post-status error-codes
--------------------------------------------------------------------------------
card(1) failed 1:0:0:0
fan(1) passed 0:0:0:0
fan(2) passed 0:0:0:0
power-supply(1) passed 0:0:0:0