beautypg.com

Interpreting the power supply leds – Cisco SFS 7008 User Manual

Page 68

background image

68

In addition, a Power Supply Identify LED is located on the outside of the chassis, next to the
corresponding power supply. This LED allows the user to initiate a command that causes the Identify
LED to blink, which assists in locating a particular Field Replaceable Unit.

Figure 5-3: Power Supply Identify LED

Replicas of the Power Supply LEDs are positioned on the back of the chassis. Refer to

“Management

Interface Module LEDs” on page 71

.

Interpreting the Power Supply LEDs

Table 5-2: Interpreting the Power Supply LEDs (see

Figure 5-2

)

Color

State

Indication

Green and
Yellow

off

No power to the power supply, or LED failure.

Green

solid on

Power Supply running with no detected errors.

Green

off

No power to the power supply, LED failure, or DC
output failure.

Yellow

off

Power Supply running with no detected errors.

Yellow

solid on

Operator intervention required. Failure detected
within the Power Supply.