beautypg.com

Run a self-test on a power supply – Cisco SFS 7008 User Manual

Page 97

background image

97

Run a Self-Test on a Power Supply

1. Show the ID of the power supply that you want to diagnose, if you do not already know the

number.
a.

Enter the show power-supply command.

Example

2. Enter the diag power-supply <id> command and specify the type of test (self-test is chosen by

default).

Example

3. Start the test.

Example

4. Use the show diag fan command to show the progress of the test.

Example

Topspin-270# show power-supply
=====================================================================
Power-supply Information
=====================================================================
ps type admin-status oper-status utilization voltage
---------------------------------------------------------------------
1 AC up up n/a 48
2 AC up up 15 47

Topspin-270> enable
Topspin-270# config
Topspin-270(config)# diag power-supply 2
Topspin-270(config-diag-power-supply-2)# test self-test

Topspin-270(config-diag-power-supply-2)# start

Topspin-270(config-diag-power-supply-2)# exit
Topspin-270(config)# exit
Topspin-270# show diag power-supply
================================================================================
Diagnostic Tests For Power Supply
================================================================================
module-type : power-supply
module-number : 2
test : self-test
iterations : 1
action : start
result : success
percentage-completed : 100
result-string : Self Test, Final report : PASSED; Please reboot syst
em
Topspin-270#