beautypg.com

Table 5-9 – Cisco SFS 7008 User Manual

Page 73

background image

73

Fan Tray Module Status LEDs

Power Supply Module Status LEDs

Green

off

No power to the Management Interface module, LED failure,
or yellow LED is ON.

Yellow

solid on

Failure of the Management Interface module. Operator
attention required.
The “!” label indicates a failure.

Yellow

blinking

Identify a Management Interface module. Assists in identifying
a particular Field Replaceable Unit on the chassis.
This state is initiated by the user.
This LED can be initiated manually by using the diag LED test.
Refer to the Command Line Reference Guide for more
information.
Example:
For example, to run the identity test on Power Supply 1:
config mode -> diag card 15 ->
test led ->
-> start - start flashing
-> stop - stop flashing

Table 5-9: Interpreting the Fan Tray Status LEDs (see

Figure 5-6

)

Color

State

Indication

Green over Yellow

off

No module power, or LED failure.

Green

solid on

Fan tray is running with no errors detected.

Green

off

No power to the fan tray, LED failure, or yellow LED is On.

Yellow

solid on

Failure of the fan tray. Operator attention required.
The “!” label indicates a failure.

Yellow

blinking

Identify a fan tray module. Assists in identifying a particular
Field Replaceable Unit on the chassis.
This state is initiated by the user.
This LED can be initiated manually by using the diag LED test.
Refer to the Command Line Reference Guide for more
information.
Example:
For example, to run the identity test on Power Supply 1:
config mode -> diag fan 1 ->
test led ->
-> start - start flashing
-> stop - stop flashing

Table 5-8: Interpreting the Management Interface Module Status LEDs (see

Figure 5-6

)

Color

State

Indication