Table 5-9 – Cisco SFS 7008 User Manual
Page 73
73
Fan Tray Module Status LEDs
Power Supply Module Status LEDs
Green
off
No power to the Management Interface module, LED failure,
or yellow LED is ON.
Yellow
solid on
Failure of the Management Interface module. Operator
attention required.
The “!” label indicates a failure.
Yellow
blinking
Identify a Management Interface module. Assists in identifying
a particular Field Replaceable Unit on the chassis.
This state is initiated by the user.
This LED can be initiated manually by using the diag LED test.
Refer to the Command Line Reference Guide for more
information.
Example:
For example, to run the identity test on Power Supply 1:
config mode -> diag card 15 ->
test led ->
-> start - start flashing
-> stop - stop flashing
Table 5-9: Interpreting the Fan Tray Status LEDs (see
Color
State
Indication
Green over Yellow
off
No module power, or LED failure.
Green
solid on
Fan tray is running with no errors detected.
Green
off
No power to the fan tray, LED failure, or yellow LED is On.
Yellow
solid on
Failure of the fan tray. Operator attention required.
The “!” label indicates a failure.
Yellow
blinking
Identify a fan tray module. Assists in identifying a particular
Field Replaceable Unit on the chassis.
This state is initiated by the user.
This LED can be initiated manually by using the diag LED test.
Refer to the Command Line Reference Guide for more
information.
Example:
For example, to run the identity test on Power Supply 1:
config mode -> diag fan 1 ->
test led ->
-> start - start flashing
-> stop - stop flashing
Table 5-8: Interpreting the Management Interface Module Status LEDs (see
Figure 5-6
)
Color
State
Indication