NE215

General structure of the error messages:

Address Line Status Error number

Example:

Address=35, Line=09 (invalid line),

Error number=2 3509R2

The two positions „Line“ and „Status“ will not occur with the
special commands.

Error description in particular:

Error 1:

Format error ( not at the right place). This

error might happen, for example, if the data format

was not observed when programming (e.g.: when

programming the limit value, only 5 instead of 6

data positions are transmitted.)

Error 2:

Line (position) not available or separating line

Error 3:

Parameter error (inadmissible values in the

protocol). This means, for example, that the limit

value consists not only of digits but also of other

inadmissible characters, or that a value given lies

outside the admissible range.

Error 4:

This error message occurs if the PC requests the

counter to print in the programming mode, if the

printout of any line except the lines 01-03 and 05

is to be initiated, or if the PC does not send Date/

Time or sends them in a wrong format. The counter

will not allow the value to be sent to the printer

and responds with an error mistake to the PC.

Example for a returned error message:

Address=35, Line=01, Error number=4

3501D4

7.8

List of the control characters used

Control character

Hex

Decimal

02

02

03

03

06

06

0A

10

0D

13

11

17

18

24

7F

127

Open interface description