11.7 Optical data
Laser
Wavelength
650 nm - 680 nm (visible red)
Pulse frequency
50 kHz
Duty cycle
50%
Average power
< 1.0 mW
Laser class
2 (to IEC 60825-1 / 2007)
Beam dimensions
at emission point
about 2.5 x 4.0 mm
Scatec-10:
70 mm beneath sensor
Line focus, 6 mm long
Scatec-15:
100 mm beneath sensor
Line focus, 8 mm long
Focus position
Scatec-10:
70 mm beneath sensor
Scatec-15:
100 mm beneath sensor
Optical receiver
equipped with near infrared suppression and daylight suppression filter
11.8 Application data
Measuring range
Scatec-10:
0 to 90 mm beneath sensor
Scatec-15:
0 to 120 mm beneath sensor
Mounting height
Scatec-10:
70 mm
Scatec-15:
100 mm
Object speed
2 m/s maximum (5 m/s maximum for thicker edges)
Minimum object spacing
10 mm @ v = 1 m/s and output pulse length 10 ms, or proportional to the
speed and output pulse length
Counting rate
1.5 million maximum copies/h (@ 2 ms output pulse length and 0 ms dead
time)
Product orientation
Folded or cut edge facing laser beam
Output pulse length
0.2 … 100 ms adjustable
Scatec-1x
Control unit
Main connector
Low-impedance
interconnection