beautypg.com

Baumer BA Scatec10 15 User Manual

Page 36

background image



User manual Scatec-10 / -15

36 / 44

Baumer Electric AG

Version 2011-03

www.baumer.com

Frauenfeld, Switzerland

Version 2

Scatec housing is grounded (use teeth lock washers
when mounting the Sactec)

Cable shield properly grounded at the controller end

Cable shield properly attached to the connector plugging
into the Scatec.

Keep the impedance of the interconnection between the
control unit’s ground and the Scatec ground sufficiently
low.










11.7 Optical data

Laser

Wavelength

650 nm - 680 nm (visible red)

Pulse frequency

50 kHz

Duty cycle

50%

Average power

< 1.0 mW

Laser class

2 (to IEC 60825-1 / 2007)

Beam dimensions

at emission point

about 2.5 x 4.0 mm

Scatec-10:

70 mm beneath sensor

Line focus, 6 mm long

Scatec-15:

100 mm beneath sensor

Line focus, 8 mm long

Focus position

Scatec-10:

70 mm beneath sensor

Scatec-15:

100 mm beneath sensor

Optical receiver

equipped with near infrared suppression and daylight suppression filter

11.8 Application data

Measuring range

Scatec-10:

0 to 90 mm beneath sensor

Scatec-15:

0 to 120 mm beneath sensor

Mounting height

Scatec-10:

70 mm

Scatec-15:

100 mm

Object speed

2 m/s maximum (5 m/s maximum for thicker edges)

Minimum object spacing

10 mm @ v = 1 m/s and output pulse length 10 ms, or proportional to the
speed and output pulse length

Counting rate

1.5 million maximum copies/h (@ 2 ms output pulse length and 0 ms dead
time)

Product orientation

Folded or cut edge facing laser beam

Output pulse length

0.2 … 100 ms adjustable

Scatec-1x

Control unit

Main connector

Low-impedance

interconnection