5 synchronization input, 6 wiring instructions – Baumer BA Scatec10 15 User Manual
Page 35

User manual Scatec-10 / -15
35 / 44
Baumer Electric AG
Version 2011-03
www.baumer.com
Frauenfeld, Switzerland
11.5 Synchronization input
•
opto-isolated input
•
input signals between 5V and 30 V
•
for NPN- or PNP-open collector, push-pull, or TTL encoder output
•
Scatec FLDM 170G…… (push-pull output)
accepts an A/B-channel encoder
•
Scatec FLDM 170C…… (opto-isolated output) accepts an A-channel encoder only.
•
synchronization input signal levels
logical high:
> 3.8 V (> 2.2 mA)
logical low:
< 1.8 V (< 0.7 mA)
•
frequency
max. 50 kHz
•
reverse polarity:
protected
11.6 Wiring instructions
In order to achieve optimum protection of the Scatec against electromagnetic interference
•
use shielded cables
•
keep the ground impedance sufficiently low
We suggest the following two grounding schemes:
Version 1
•
Scatec housing is grounded (use teeth lock washers when
mounting the Sactec).
•
Cable shield not grounded at the controller end.
•
Cable shield properly attached to the connector plugging
into the Scatec.
Pin 5
( Pin 2 )
Scatec
Pin 4
Pin 2
(FLDM 170G...
only! )
positive
negative
positive
Pin 4
Pin 5
( Pin 2 )
Pin 4
+ V
E
+ V
E
Pin 5
( Pin 2 )
Pin 4
+ V
E
Pin 5
GND
E
GND
E
GND
E
Pin 5
( Pin 2 )
Pin 4
+ V
E
GND
E
NPN open
collector
PNP open
collector
Push-pull
TTL
Scatec-10/ -15
Main connector
+ V
E
: Output voltage of the encoder
GND
E
:
GND of the encoder
S
c
a
te
c
-1
0
/-1
5
M
a
in
c
o
n
n
e
c
to
r
S
c
a
te
c
-1
0
/-
1
5
M
a
in
c
o
n
n
e
c
to
r
S
c
a
te
c
-1
0
/-1
5
M
a
in
c
o
n
n
e
c
to
r
S
c
a
te
c
-1
0
/-1
5
M
a
in
c
o
n
n
e
c
to
r
Scatec-1x
Controller
Main connector