10.3.3 Menu C:
Parameters
[Parametrs]
Operational parameters are set in menu C. A detailed description of these parameters is given in section 9
Setting the operational parameters.
•
Submenus not applicable in the present setting will be skipped in the display!
•
With the sensor locked, no parameters can be changed while navigation is still possible. The sensor can
be unlocked in menu B. When trying to change a parameter of a locked Scatec, the message “input
locked” will show up as reminder.
•
The sensor will be locked again if no key is pressed for 30 minutes
Submenu
values
Comments
C0:
Pulse Length
xx.x ms
Output pulse length in ms
value of output pulse length in milliseconds
C1:
RunDirection
0 = lead
1 = trail
Running direction of the copies
leading
trailing
C2:
Fp-Suppress
0 = off
1 = on
False pulse suppression
no false pulse suppression mode will be activated
a false pulse suppression mode as defined in [C3]
will be activated
C3:
Suppr.Mode
00 = dyn
01 = sync
02 = fixed
03 = reflx
False pulse suppression mode
dynamic
synchronous
fixed
retro-reflective foil only
C4:
Dead Time %
xxx
Dead time in percentage
value of dynamic dead time in percentage of the mean
interval between copies
C5:
Encodr Resol
x.xx mm
Encoder resolution in mm/pulse
value of encoder resolution in millimeters per
encoder pulse
C6:
Dead Path mm
xxx mm
Dead path in mm
value of synchronized dead path mm
C7:
Encoder A/B
0 = off
1 = on
Encoder A/B
only A-channel of encoder is used
A- and B-channels of encoder are used
C8:
Dead Time ms
xxx ms
Dead time in ms
value of fixed dead time in milliseconds
C9:
Pulse Delay
0 = off
1 = on
Output pulse delay
output pulse issued immediately after end of the edge
output pulse issued with delay relative to end of the
edge