Flow chart for setting the operational parameters – Baumer BA Scatec10 15 User Manual

Page 13

background image



User manual Scatec-10 / -15

13 / 44

Baumer Electric AG

Version 2011-03

www.baumer.com

Frauenfeld, Switzerland

Flow chart for setting the operational parameters


FLDM 170G....

FLDM 170C....

C2 False Pulse

Suppression

0 = off
1 = on

C3 Suppression

Mode

00 dynamic
01 synchronous
02 fixed
03 reflective

C4 Dead Time

[%]

value

18

C7 Encoder A/B

0 = off (A only)
1 = on (A/B)

C8 Dead Time

[ms]

value

20

C9 Pulse Delay

0 = off
1 = on

C10 Pulse Delay

[ms]

value

100

C11 Pulse Delay

[mm]

value

100

C14 Short Pulse

Suppression

0 = off
1 = on

C13 Tail Edge

Suppression

0 = standard

1 = extended

C9 Pulse Delay

0 = off
1 = on

C12 Output at End

of Pulse Train

0 = first
1 = last

C0 Pulse

Length [msec]

value

10.0

Operational

parameters are set !

C Parameters

C1 Running

Direction

0 = leading
1 = trailing

C15 Sensitivity Mode

0 = standard
1 = customized

C16 Sensitivity

Setting

01 high
02 medium
03 low
04 very low

C17 Threshold

value

179

C18 Hysteresis

value

32

Operational

parameters are set !

C5 Encoder

resolution [mm/pulse]

value

1

C6 Dead Path [mm]

value

20






Default values are underlined. In most cases, the default setting will provide good results.
The factory preset default values can be reset anytime in submenu F4.
The names in the flow chart appear on the display as shown in square brackets in the next section.