11.2 Electrical data

Operating voltage V

S

Limits:

+10 VDC to +30VDC

Reverse-protected

yes

Ripple V

S

10% within the limits of V

S

Power consumption

< 2 W

Current consumption

Average:

< 170 mA

Peak (after switching on)

< 180 mA

Connectors

Main connector

DIN 45322, 6-pole, male

Interface connector

DIN 45326, 8-pole, male

Output circuit

FLDM 170G...

push-pull

normal state

low

FLDM 170C...

opto-isolated

switchable voltage

maximum 40 V

Load resistance

maximum 50 kOhm

Current load:

max. 100 mA

Short-circuit protected

yes

Output pulse length

selectable 0.3 … 100ms

11.3 Pin assignment (looking at connector on Scatec)




Main connector

DIN 45322, 6 pole, male





Interface connector

DIN 45326, 8 pole, male












Pin

Assignment

1

output signal +Vout

2

encoder input B

(FLDM 170G...)

output signal -Vout

(FLDM 170C...)

3

operating voltage +Vs

4

encoder GND

5

encoder input A

6

operating voltage GND (0V)

Pin

Assignment

1

CAN_H

2

not connected

3

serial TxD (sensor)

4

CAN_L

5

serial RxD (sensor)

6

CAN_GND

7

serial GND

8

GND

3

4

2

1

5

6

6

4

1

2

3

5

7

8