10.3.4 Menu D:
Interface
[Interface]
Parameters concerning the CAN-interface are set in menu C
Only Scatec-15 is equipped with a CAN interface.
Submenu
Values
Comments
D2:
CAN Baud
00 = 10 kBaud
01 = 20 kBaud
02 = 50 kBaud
03 = 100 kBaud
04 = 125 kBaud
05 = 250 kBaud
06 = 500 kBaud
07 = 800 kBaud
08 = 1000 kBaud
CAN Baudrate
default value:
01 = 20 kBaud
D3:
CAN-Node-Id
xxx
CAN-Node-Id
Node-ID must be a number between 1 and 127
(default value:
1)
10.3.5 Menu E:
Counter
[Counters]
In menu E, several counters can be read and reset.
Submenu
Values
Comments
E1:
Copy Counter
xxxxxxxx
Copy counter
Total number of counted edges or output pulses since
last reset
E2:
marg.counted
xxxxxxxx
Marginally counted edges
Total number of edges which where counted but which
dropped only marginally below threshold
E3:
marg. missed
xxxxxxxx
Marginally missed edges
Total number of edges which were not counted because
they marginally missed the threshold
E4:
Reset Cntrs.
0
= no
1 = yes
Counter reset
counters will not be reset
counters will be reset to 0
The counters are automatically reset upon power up of
the sensor