5 Technical data

Technical data - electrical ratings

Voltage supply

21...53 VAC (50/60 Hz) or

10.5...70 VDC

85...265 VAC (50/60 Hz) or

100...300 VDC

Power consumption

2.2 W

Sensor supply

5 V, 8 V or 12 V

programmable/60 mA

Display

LED, 7-segment display (with 60 unit

stickers for front)

Number of digits

4-digits

Digit height

10 mm

Display range

9999 („OuE“ to signal overflow)

Display refresh

0.1... 9.9 s (programmable)

Programmable

Measuring units 1/h, 1/min, 1/s

parameters

Sensor logic

Decimal point

Sensor supply

Impulse evaluation

Measuring principle

Period duration measurement

Signal inputs

Programmable as NPN, PNP, Namur,

TTL, 10...600 VAC or contact

Counting frequency

0.01 Hz...7 kHz (20 Hz if contact input)

Data memory

>10 Jahre in EEPROM

Standard

Protection class II

DIN EN 61010-1

Overvoltage category II

Pollution degree 2

Emitted interference

DIN EN 61000-6-3

Interference immunity

DIN EN 61000-6-2

Technical data - mechanical design
Ambient temperature

-10...+60 °C

Storing temperature

-25...+85 °C

Relative humidity

95 % non-condensing

Connection

Spring-loaded terminal connector,

detachable

Core cross-section

1 mm² (grid 2.54)

2.5 mm

2

(grid 7.62)

Protection DIN EN 60529

IP 65 (face)

Operation / keypad

3 softkeys below bezel

Housing type

Built-in housing

Dimensions W x H x L

48 x 24 x 106 mm

Mounting

Front panel installation by clip frame

Material

Housing: Polycarbonate, UL 94V-0

Weight approx.

50 g