Baumer TA1200 User Manual
Page 17
![background image](/manuals/604465/17/background.png)
TA1200
www.baumer.com
17
3.2 Inputs and outputs
Signal input
Specification
PNP
High level >2.6 V
Low level <2.4 V
Input resistance 1.5 kΩ
NPN
High level >2.6 V
Low level <2.4 V
Input resistance 3.9 kΩ
TTL
High level >2.6 V
Low level <2.4 V
NAMUR
Ion <1 mA, Ioff >3 mA
Input resistance 1.5 kΩ
Magnetic sensor
Vin >30 mVeff at 60 Hz
Vin >300 mVeff at 6 kHz
Contact
Input resistance 3.9 kΩ
Voltage 10...600 VAC
Measuring the frequency of the
voltage
3.3 Voltage supply connection
There are several options for operation supply. Power supply must
be fed in via the recommended external fuse.
Operating voltage
External protection
85...265 VAC, (50/60 Hz) and 100...300 VDC
M 100 mA
21...53 VAC, (50/60 Hz) and 10.5...70 VDC
M 500 mA