Baumer TA1200 User Manual
Page 21
![background image](/manuals/604465/21/background.png)
TA1200
www.baumer.com
21
Decimal point
No decimal point
Decimal point at first digit
4.2.3 Scaling of displayed value (rAtE)
Here, the displayed value is to be assigned an input frequency to cal-
culate the ratio between these two. The displayed value is calculated
by input frequency multiplied by ratio with two selection options: Di-
rect proportional to input frequency and inverted proportional to in-
put frequency.
Display behavior
Direct proportional to input frequency
Inverted proportional to input frequency
Direct proportional Displayed value will be increasing with the input frequency.
Application example: Displaying the production time 1/h.
Display-
value
Frequency
Inverted proportional Displayed value will be descending with increasing input frequency.
Application example: Displaying the oven processing time.
Display-
value
Frequency
Input frequency
Enter the input frequency within the range 1 to 9999.
Decimal point in the input frequency
Select decimal point in the input frequency.
Displayed value
Enter displayed value which corresponds to the frequency parameter
in InP 1.
Decimal point in the displayed value
Select decimal point position in the displayed value.