16
www.baumer.com
2 Description
2.1 System description
Intended use of the tachometer: Displaying frequencies and speed
in industrial applications.
-Reading programmable as 1/s, 1/min, 1/h
-Input: NPN, PNP, Namur, TTL, 10…600 VAC
-Sensor supply 5 V, 8 V, 12 V
-Frequency 0.01 Hz…7 kHz
-Period duration measurement
-LED display, 4-digits
-DIN housing 48 x 24 mm
2.2 Display
4 digits
Sticker to indicate measuring unit
3 Connection
This chapter is about terminal assignment and will present some wi-
ring examples.
3.1 Terminal assignment
6XSSO\YROWDJH
&RPPRQ9
,PSXOVHLQSXW
999
QF
9$&
Litz contact only by means of connector sleeves with insulating
enclosures for reasons of shock protection according to EN 61010.
Do not otherwise assign contacts that have been left unassigned ex
factory. We recommend to screen all sensor terminal leads and to
ground the shield on one side. Shields on both sides are recommen-
ded in case of RF interference or in case of equipotential bonding
over long distances. The sensor leads should not be in the same
phase winding as the mains supply and the output contact leads.