2.1 System description
Intended use of the tachometer: Displaying frequencies and speed

in industrial applications.

-Reading programmable as 1/s, 1/min, 1/h

-Input: NPN, PNP, Namur, TTL, 10…600 VAC

-Sensor supply 5 V, 8 V, 12 V

-Frequency 0.01 Hz…7 kHz

-Period duration measurement

-LED display, 4-digits

-DIN housing 48 x 24 mm

2.2 Display

4 digits

Sticker to indicate measuring unit

3 Connection

This chapter is about terminal assignment and will present some wi-

ring examples.

3.1 Terminal assignment

6XSSO\YROWDJH

&RPPRQ9

,PSXOVHLQSXW

999

QF

9$&





Litz contact only by means of connector sleeves with insulating

enclosures for reasons of shock protection according to EN 61010.

Do not otherwise assign contacts that have been left unassigned ex

factory. We recommend to screen all sensor terminal leads and to

ground the shield on one side. Shields on both sides are recommen-

ded in case of RF interference or in case of equipotential bonding

over long distances. The sensor leads should not be in the same

phase winding as the mains supply and the output contact leads.