beautypg.com

Humboldt H-4140 GeoGauge User Manual

Page 38

background image

38

Humboldt GeoGauge® Data Download Guide

For use with C series Humboldt GeoGauge

Purpose

To download data from the C series Humboldt H-4140 GeoGauge to a PC.
Equipment Required

• H-4140.12 Infrared Interface to serial port cable
• USB to serial port adapter (optional)
• Any PC running any version of Windows with HyperTerminal
Operation

Initial Setup
1) Attach the GeoGauge Infrared Interface Cable to a 9 pin serial port on the

personal computer (PC) or to a USB port via an appropriate adapter

(Figures 1, 2 & 3).

2) Attach the GeoGauge Infrared Interface Cable reader head to the slotted

retainer on the top of the GeoGauge. Be sure that the two infrared windows

line up (Figure 4).

3) Turn on GeoGauge and PC.
4) On the PC monitor, click “Start”, highlight “Accessories”, click

“Communications”, and click “HyperTerminal”. HyperTerminal is the

Windows terminal emulation program.

5) Enter a distinct file name for the GeoGauge download settings.

For example:“GeoGaugeDownload”. Select an appropriate icon. Click

“OK”. It is through this new connection setting that all download data can

be entered repeatedly without having to re-enter the settings every time.

6) In the “Connect To” window, select “connect using”. Highlight the

COM port to which the Infrared Interface Cable is connected. Click “OK”.

7) In the “COM Properties” dialog box under the “Port Settings” tab, show:

• Bits per second: 4800 (for GeoGauge serial numbers less than 326) or

1200 (for GeoGauge serial numbers greater than or equal to 327)

• Data bits: 8

• Parity: none

• Stop bits: 1

• Flow control: Hardware

Click “OK”; click “File” and then click “Save”.