17

6/23/2010

Front

Parts

166-263M

Actuator Channel Setup

85. Assign material.

86. Type must be set to GRAN SEED CONTROL or

GRAN FERT CONTROL.

87. Check that other setting are as Required, and

reflect the actual configuration of the implement.

Example Channel Setup:

Parameter

Value

Comment

CHANNEL

1 or 2

Per meter
being config-
ured

Type

GRAN SEED CONTROL
or
GRAN FERT CONTROL

One of these
Required

Material
Name

Wheat HRW
or
11-52-0

Example
user-speci-
fied names

Control
Mode

Auto

Required

Drive Type

Zero Max 1 or 2

Required

Drive Freq.

40

Hz

Required

Input Fliter

50

%

Required

Sensor
Constant

360

PUL/REV

Required

Gear Ratio

1

Required

Meter Gear
Range

LOW or HIGH

One of these
Required

# Seed
Rows

32, 36, 40, 48, 50, 60, 65,
66, 80

read-only, per
implement or
drill model

Channel
Width

(set to swath of imple-
ment or drill, in inches or
cm)

Required

Flush
Enable

Disabled

Data not used

Pre-
charge(+)\D
elay(-)

0.0

SEC

Data not used