Install quickfill assembly, Connect quickfill assembly – Great Plains NP3000A Predelivery Manual User Manual
Page 15

Great Plains Manufacturing, Inc.
Install Sub-Frame
11
03/31/2011
407-613Q
Install Quickfill Assembly
Refer to Figure 13 and Figure 14
1.
Select one:
407-587S QUICKFILL ASSY
and three sets:
802-034C HHCS 1/2-13X1 1/4 GR5
804-015C WASHER LOCK SPRING 1/2 PLT
803-020C NUT HEX 1/2-13 PLT
2.
At the left end of the tank sub-frame, install the
quickfill assembly
at the 2nd, 3rd and 4th mount-
ing holes (from the front).
Connect Quickfill Assembly
Refer to Figure 15
3.
Locate the hose to the pump
and its clamp:
800-259C CLAMP WRM DRV#36SS (1.81-2.75)
Route the hose to the outlet of the strainer. Secure
with clamp. Do not over-tighten. This is a low-pres-
sure line.
4.
Reconnect the line
between the supply tee and
the selector valve. The line is open at only one or two
connections, but is shown exploded, as the break
location may vary between shipments.
Figure 13
407-587S Quickfill Assembly
32037
27
27
31
43
37
27
Figure 14
Quickfill Mounting
31931
27
31
43
37
Figure 15
Quickfill Connections
32038
26
5
2
29
29