For installation assistance, contact SARGENT at 800-810-WIRE (9473)
Additional Keypad Programming
5
To Disable the RF Receiver:
Depress (up to 3 seconds) the # sign on the keypad until you hear 3 beeps and the yellow LED blinks
continually. RF Receiver is now in program mode.
RF Program Code
#
Yellow LED double blinks
903
#
Yellow LED double blinks
00000
#
Yellow LED double blinks
00000
#
3 Beeps & Yellow LED double blinks
#
5 Beeps & Yellow LED goes out
Note: When the RF Receiver has been disabled and an RF signal is detected from
an RF FOB, the lock will beep 5 times (rapidly) to indicate that it is in disabled mode.
To Enable the RF Receiver:
Depress (up to 3 seconds) the # sign on the keypad until you hear 3 beeps and the yellow LED blinks
continually. RF Receiver is now in program mode.
RF Program Code
#
Yellow LED double blinks
913
#
Yellow LED double blinks
00000
#
Yellow LED double blinks
00000
#
3 Beeps & Yellow LED double blinks
#
5 Beeps & Yellow LED goes out
To Change the Red LED Actuation Indicator Duration:
Press (up to 3 seconds) the # sign on the keypad until you hear 3 beeps and the yellow LED blinks continually.
RF Receiver is now in program mode.
Note: The Red LED (located on the inside escutcheon) default duration is 10 seconds.
RF Program Code
#
Yellow LED double blinks
971
#
Yellow LED double blinks
Duration (1-99 Seconds)
#
Yellow LED double blinks
Duration (1-99 Seconds)
#
3 Beeps & Yellow LED blinks
#
5 Beeps & Yellow LED goes out
To Delete an RF Technology User:
99
#
Master Code
*
Yellow LED blinks
50
#
1
#
User Number (04-500)
#
Yellow LED blinks
*
Yellow LED blinks quickly
*
Yellow LED blinks slowly
*
Yellow LED goes out